Load board design takes into consideration many factors, one of which is power supply routing.  It is good practice to assign a separate power plane for every supply voltage needed by the DUT, even if two or more supplies will be tied up to the same nominal voltage.  This has two advantages: 1) noise immunity between power supplies and 2) the ability to assign each power supply to a different voltage later on. Adding sense lines as close as possible to the DUT to each power plane for output monitoring would also be helpful. Put decoupling capacitors between each power supply pland and the ground plane to reduce power supply noise.  Note that the values of the capacitors must be chosen based on the operation frequencies of the DUT.

 

Signal routing is another consideration in the design of a load board.  Avoid overlaying power supply planes over signal planes. There are two types of DUT signals, and guidelines for handling them in a load board differ. The first type, the low-speed digital signal, doesn't require much as far as load board design goes. Digital signals can share the same plane, but they should have their own plane. The lengths of their traces should be the same. 

                                                         

   

Fig. 2.  Photos of load boards used for calibration

and engineering purposes only

                              

The second type of DUT signal is the high-performance signal.  This signal type requires high-performance instrumentation for measurement, because the speed and accuracy of these signals could not be handled by the ATE. Keep the length of the cable connecting the DUT to the load board as short as possible.  Avoid parallel runs of mixed signals as well, to avoid noise coupling. Needless to say, high-performance signals need a signal plane of their own.

  

Load boards require connectors for cables that run to the test site.  High-speed applications commonly employ SMA and SSMB connectors. Higher bandwidth applications are better off using the SMA connector, since this screw-on/screw-off type of connector is larger and designed for higher bandwidth than the SSMB connector, which is a push/pull type of connector. SMA is also sturdier on the load board and can withstand a greater deal of mechanical stresses.

   

Decoupling capacitors must be placed as close to the DUT as possible - preferably directly under the socket. AC coupling capacitors and termination resistors must likewise be as close to the DUT as possible. The use of surface-mounted components is also recommended for load boards. Power supplies used for load boards must have enough power to energize all relays on the board.

             