Subgroup |
Tests /Conditions |
SS |
Accept # |
|
Subgroup
1
|
a.
Physical Dimensions - Mil-Std-883 Method 2016
|
15 |
0 reject |
|
Subgroup
2
|
a.
Lead Integrity - Mil-Std-883 Method 2004
- test condition B2 (Lead Fatigue)
|
45 |
0 reject |
|
b.
Seal Integrity - Mil-Std-883 Method 1014
1)
Fine Leak Test
2) Gross
Leak Test
|
45 |
0 reject |
|
Subgroup
3
|
a.
Thermal Shock - Mil-Std-883 Method 1011
- test condition B min.; 15X min.
|
15 |
0 reject |
|
b.
Temperature Cycle - Mil-Std-883 Method 1010
- test
condition C, 100X min.
|
15 |
0 reject |
|
c.
Moisture Resistance - Mil-Std-883 Method 1004
|
15 |
0 reject |
|
d.
Visual Inspection - per criteria in Mil-Std-883 Methods 1004 and
1010
|
15 |
0 reject |
|
e.
Seal Integrity - Mil-Std-883 Method 1014
1)
Fine Leak Test
2) Gross
Leak Test
|
15 |
0 reject |
|
f.
End-point electrical parameters
- Per
the applicable device specifications
|
15 |
0 reject |
|
Subgroup
4
|
a.
Mechanical Shock - Mil-Std-883 Method 2002
- test
condition B min.
|
15 |
0 reject |
|
b.
Vibration Test, Variable Frequency - Mil-Std-883 Method 2007
- test
condition A min.
|
15 |
0 reject |
|
c.
Constant Acceleration - Mil-Std-883 Method
2001
- test
condition E min.
|
15 |
0 reject |
|
d. Seal
Integrity - Mil-Std-883 Method 1014
1)
Fine Leak Test
2) Gross
Leak Test
|
15 |
0 reject |
|
e.
Visual Inspection - per criteria in Mil-Std-883 Methods 1010 or
1011
|
15 |
0 reject |
|
f.
End-point electrical parameters
- Per
the applicable device specifications
|
15 |
0 reject |
|
Subgroup
5
|
a.
Salt Atmosphere Test - Mil-Std-883 Method 1009
|
15 |
0 reject |
|
b.
Visual Inspection - per criteria in Mil-Std-883 Method 1009
|
15 |
0 reject |
|
c.
Seal Integrity - Mil-Std-883 Method 1014
1)
Fine Leak Test
2) Gross
Leak Test
|
15 |
0 reject |
|
Subgroup
6
|
a.
Internal Water Vapor Content - Mil-Std-883 Method 1018
- 5,000
ppm max water content at 100C
|
3 (or 5) |
0 reject
for SS=3;
1 reject
for SS=5 |
|
Subgroup
7
|
a.
Adhesion of Lead Finish - Mil-Std-883 Method 2025
|
15 |
0 reject |
|
Subgroup
8
|
a.
Lid Torque Test - Mil-Std-883 Method 2024
|
5 |
0 reject |